Order No
101208309
Certificates
IFA cULus CCC TILVA
Schmersal
Safe Signal Processing
Security Relay and Control Modules
SRB211ST (V2) Security Relay and Control Modules
Schmersal SRB211ST (V2) features -25 ... +60 °C ambient temperature and 121 mm depth.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×100mm×121mm
- • Weight: 280 g
- • Certification: IFA cULus CCC TILVA
- • Contacts: 2 NC
Standards
- • EN IEC 60947-5-1
- • EN IEC 61508
Product Features
- • 2 safety contacts, STOP 0; 1 safety contact, STOP 1
- • 1 signal output
- • Suitable for the signal processing of outputs with contact sensors
- • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
SIL Stop 0
3
SIL Stop 1
2
Height
100 mm
PFD Value
5.30 x 10⁻⁵
Number of LEDs
6
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system, emergency stop button, pull-wire emergency stop switches, safety light curtain
Mission time
20 Year(s)
Category Stop 0
4
Category Stop 1
3
Gross weight
280 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgSn0, Ag-Ni, self-cleaning, positive drive
Start Input
Yes
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
DC Level Stop 0
≥ 99 %
DC Level Stop 1
> 60 %
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
PFH Value Stop 1
2.00 x 10⁻⁷ /h
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-78
Ripple Voltage
10 %
Stop Category
0 1
Ambient Temperature
-25 ... +60 °C
Reset Edge Detection
Yes
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Connection Diagram Note
The hinge axis must be 11 mm above. Minimum actuating radius 45 mm with AF 2,5 mm hexagon key (a).
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
3
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
3 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
2 A
Performance Level Stop 0
e
Performance Level Stop 1
d
Overvoltage category
III
Electrical Power Consumption
5.9 VA
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Number of Signal Outputs
1
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
Removable Terminals
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Rated impulse withstand voltage (Uimp)
4 kV
Emergency Release Delay
30 ms
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
Number of Safety Contacts STOP 0
3
Number of Safety Contacts STOP 1
2
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Position relay K2 Position relay K1 Internal operating voltage Ui Position relay K3/K4
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
250 ms