SRB219IT-24VAC/DC
Order No 101158208
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SRB219IT-24VAC/DC

SRB219IT-24VAC/DC — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +45 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101158208. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 360 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-5
  • • EN IEC 60947-5-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1
  • • EN ISO 13849-1
  • • EN IEC 62061

Product Features

  • • Multifunctional safety relay module for superior diagnostics and visualisation
  • • Suitable for the signal processing of outputs with contact sensors
  • • Suitable for the signal processing of outputs with contact sensors
  • • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • • 1 + 8 Signalling outputs
  • • 2 safety contacts, STOP 0;1 safety contact, STOP 1 (adjustable 1 … 30 s)

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
EMC rating EMC-Directive
Height 100 mm
Start input Yes
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type AC | DC
Shock resistance 30 g / 11 ms
Stop-Category 1 | 0
Mission time 20 Year(s)
Net Ağırlık 360 g
Number of LEDs 7
Ripple voltage 10 %
Climatic stress EN 60068-2-78
Electronic Fuse Yes
Frequency range 50 Hz | 60 Hz
Gross weight 360 g
Category, Stop 0 4
Category, Stop 1 3
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VAC -15 % / +10 %24 VDC -15 % / +20 %
PFH value, Stop 0 2.00 x 10⁻⁸ /h
PFH value, Stop 1 2.00 x 10⁻⁷ /h
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Operating current 200 mA
Ambient Temperature -25 ... +45 °C
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Reset edge detection Yes
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) For 2-channel control with cross-wire monitoring, connect the NC contact to S11/S12 and S31/S32 and bridge S21/S22 | F2 = Fuse for signalling outputs | For 1-channel control, connect NC contact to S11/S12 and bridge S21/S22 + S31/S32 | Early switch-off of time delay: The drop-out delay time can be ended early via the input RT. The input RT makes it possible to "switch off" the time-delayed enabling circuit 37/38 before the set time has elapsed." | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2). (example without cross-wire monitoring) | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | Setting of the drop-out delay time is carried out by means of a potentiometer from the front of the enclosure. | "Start function / Reset button: The function "trailing edge" is programmed by means of the "AF" switch located underneath the housing cover (switch position = 1). The automatic start is programmed by bridging terminals X3/X5 and by switching the "AF" swit | F1 = Hybrid fuse | The control system recognises wire-breakage and earth faults in the monitoring circuit. | Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. | Time delay: The time-delayed safety enable 37/38 is adjustable for 1 to 30 seconds drop-out delay (see setting intructions). | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 3
Maks. Ortam Sıcaklığı +45 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Internal operating voltage Ui | Position relay K3 | Position relay K5 | Position relay K2
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 1
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VAC | 24 VDC | 24 VAC -15% / +10% | 24 VDC -15% / +20%, residual ripple max. 10 %
Electrical power consumption 5.2 VA | 4.4 W
Number of signalling outputs 8
Note (application conditions) Safety light curtain | Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Performance Level, stop 0, up to e
Performance Level, stop 1, up to d
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Pull-in delay at RESET, typically 200 ms
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Rated control voltage at DC, maximum 28.8 VDC
Number of NC (Normally Closed) Contacts 2
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
Diagnostic Coverage (DC) Level, Stop 1 > 60 %
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 26.4 VAC
Rated control voltage at AC 60 Hz, maximum 26.4 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
Rated AC voltage for controls, 60 Hz, minimum 20.4 VAC
IP Degree of protection of the installation space IP54
Drop-out delay in case of "emergency stop", maximum 15 ms
Pull-in delay at automatic start, maximum, typically 60 ms
Number of delayed semi-conductor outputs with signaling function. 1
Number of undelayed semi-conductor outputs with signaling function 7
Safety Integrity Level (SIL), Stop 0, suitable for applications in 3
Safety Integrity Level (SIL), Stop 1, suitable for applications in 2

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3