SRB301HC/T-230V
Order No 101190595
Article Code 101190595
Certificates TÜV cULus CCC TILVA
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB301HC/T-230V

Product Description

  • • Voltage: 48 ... 240 VAC | Dimensions: 45mm×100mm×121mm | Weight: 300 g | Contacts: 2 NC

Standards

  • • EN IEC 60947-5-1 EN IEC 61508

Product Features

  • • 3 güvenlik kontağı, STOP 0_x000D_
  • • 1 sinyal çıkışı_x000D_
  • • Suitable for the signal processing of outputs with contact sensors

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning Discontinued product
Depth 121 mm
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 45 mm
SIL Stop 0 3
Height 100 mm
Number of LEDs 4
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Protection system Acil durdurma butonu Pull wire acil durdurma switch Safety safety mats
Mission Time 20 Year(s)
Category Stop 0 4
Gross Weight 300 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material AgSn0. self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0 ≥ 99 %
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Terminal (Mechanical) Threaded terminal block
Climatic Resistance EN 60068-2-78
Stop Category 0
Ambient Temperature -25 ... +60 °C
Operating Voltage 48 ... 240 VAC
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Spare Article Number 101193479
Voltage Range Type AC
Connection Diagram Note Evaluation requirements: switch-off pauses of 250 µs - 1500 µs must be tolerated. The safety sensor's 250 µs switch-off time is extended according to cable length. Typically 500 µs is achieved with 100 m of cable.
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.25
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 0.25
Performance Level Stop 0 e
Number of Auxiliary Contacts 1
Overvoltage Category III
Electrical Power Consumption 5.1 VA
Min. Switching Capacity 10 mA
Rated Operating Voltage 48 ... 240 VAC
AC Control Voltage 50Hz min. 48 VAC
AC Control Voltage 60Hz min. 48 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 240 VAC
AC Control Voltage 60Hz max. 240 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Min. Common Cause Failure (CCF) 65
Displayed Operating States Konum relay K2 Konum relay K1
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 100 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.