SRB301MC-24V
Order No 101190684
Article Code 101190684
Certificates TÜV cULus CCC
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB301MC-24V

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 269 g | Contacts: 2 NC

Standards

  • • EN IEC 60947-5-1 EN IEC 61508

Product Features

  • • 3 güvenlik kontağı, STOP 0_x000D_
  • • 1 sinyal çıkışı_x000D_
  • • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains_x000D_
  • • Suitable for the signal processing of outputs with contact sensors

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
Width 22.5 mm
SIL Stop 0 3
Height 100 mm
Number of LEDs 4
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Protection system Acil durdurma butonu Pull wire acil durdurma switch Safety light curtain
Mission Time 20 Year(s)
Category Stop 0 4
Gross Weight 269 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material AgSn0, Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
DC Level Stop 0 ≥ 99 %
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Terminal (Mechanical) Threaded terminal block
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +60 °C
Operating Voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Max. Installation Altitude 2,000 m
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.25
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 0.25
Performance Level Stop 0 e
Number of Auxiliary Contacts 1
Overvoltage Category III
Electrical Power Consumption 4.9 VA
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
Max. RESET Pull-In Delay 20 ms
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 15 ms
DC Min. Rated Control Voltage 20.4 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Konum relay K2 Konum relay K1 Internal operation voltage U i Operation voltage U B
Emergency Stop Release Delay (Max.) 25 ms
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 100 ms
Max. Pull-In Delay on Automatic Start 160 ms