SRB301X4-24V
Order No 101181894
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SRB301X4-24V

SRB301X4-24V — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +60 °C | -30 ... +60 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101181894. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 450 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-1
  • • EN IEC 60947-5-5
  • • EN IEC 62061
  • • EN ISO 13849-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1

Product Features

  • • Suitable for the signal processing of outputs with contact sensors
  • • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • • 3 safety contacts, STOP 0
  • • 1 Signalling output

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
Category 4
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
PFH value 2.00 x 10⁻⁸ /h
EMC rating EMC-Directive
Height 100 mm
Start input Yes
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type AC | DC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 450 g
Number of LEDs 3
Ripple voltage 10 %
Climatic stress EN 60068-2-78
Electronic Fuse Yes
Frequency range 50 Hz | 60 Hz
Gross weight 450 g
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VAC -15 % / +10 %24 VDC -15 % / +20 %
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Max. cable cross-section 2.5 mm²
Ambient Temperature -25 ... +60 °C | -30 ... +60 °C
Performance level e
Mechanical life (min.) 10,000,000
Utilisation category AC-15 | DC-13
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) (H2) = Feedback circuit | The control recognises cross-short, cable break and earth leakages in the monitoring circuit. | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | 2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R). | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 3
Maks. Ortam Sıcaklığı +60 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Position relay K2
Utilization Category AC-15 6 A | 230 VAC
Utilization Category DC-13 6 A | 24 VDC | 24 VDC / 6 A
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 1
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VAC | 24 VDC | 24 VAC -15% / +10% | 24 VDC -15% / +20%, residual ripple max. 10 %
Electrical power consumption 4 VA | 2 W
Note (application conditions) Pull-wire emergency stop switches | Emergency-Stop button | Safety light barriers | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Diagnostic Coverage (DC) Level > 99 %
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Pull-in delay at RESET, typically 20 ms
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Rated control voltage at DC, maximum 28.8 VDC
Number of NC (Normally Closed) Contacts 2
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 26.4 VAC
Rated control voltage at AC 60 Hz, maximum 26.4 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
Rated AC voltage for controls, 60 Hz, minimum 20.4 VAC
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 40 ms
Drop-out delay in case of "emergency stop", maximum 20 ms
Safety Integrity Level (SIL), suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3