Schmersal SRB303SQP-SS-24V
Order No 103008086
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB303SQP-SS-24V Security Relay and Control Modules

Schmersal SRB303SQP-SS-24V features -25 ... +60 °C ambient temperature, rigid or flexible Screw connection / plug-in terminal connection and 121 mm depth.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 45mm×120mm×121mm
  • • Weight: 480 g

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • Signal processing of safety edges of the STW-SL series
  • • 3 safety contacts, STOP 0
  • • 3 signal outputs

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 45 mm
SIL Stop 0 3
Height 120 mm
PFD Value 1.80 x 10⁻⁴
Number of LEDs 4
Shock resistance 10 g / 11 ms
EMC Class EMC Directive
Application Note Safety edges
Mission time 20 Year(s)
Category Stop 0 3
Gross weight 480 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0 ≥ 99 %
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.5 Nm
Max. cable cross-section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Ripple Voltage 10 %
Stop Category 0
Ambient Temperature -25 ... +60 °C
Reset Edge Detection Yes
Operating voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions EN 60947-1
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Terminal connection rigid or flexible Screw connection, plug-in
IP Protection (Mounting Area) IP54
Current Utilization Cat. AC-15 6 A
Current Utilization Cat. DC-13 6 A
Performance Level Stop 0 e
Number of auxiliary contacts 3
Overvoltage category III
Electrical Power Consumption 7.5 VA
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Rated impulse withstand voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 15 ms
DC Min. Rated Control Voltage 20.4 VDC
Number of Safety Contacts STOP 0 3
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Internal operating voltage Ui, position relay K1/K2, UB: supply voltage on
Release Delay on Power Failure 50 ms
Pull-In Delay on Automatic Start 80 ms