SRB401EM115V
Order No 101183481
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SRB401EM115V

SRB401EM115V — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +50 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101183481. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 260 g

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-5
  • • EN IEC 62061
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1

Product Features

  • • Expander module for contact expansion
  • • 4 safety contacts, STOP 0
  • • 1 Signalling output

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 22.5 mm
EMC rating EMC-Directive
Height 100 mm
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type AC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 260 g
Number of LEDs 1
Climatic stress EN 60068-2-78
Frequency range 50 Hz | 60 Hz
Gross weight 260 g
Category, Stop 0 4
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 115 VAC -15 % / +6 %
PFH value, Stop 0 2.00 x 10⁻⁸ /h
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Operating current 50 mA
Ambient Temperature -25 ... +50 °C
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) Relay outputs: 1-channel control of the expander module is suitable for contact reinforcement or multiplication of the connected safety relay module. | Terminals X1 and X2 of the expander module must be connected to the feedback circuit or reset circuit of the safety relay module. | The wiring diagram shows the control of the expander module by a SRB... safety relay module with the guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 4
Maks. Ortam Sıcaklığı +50 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1/K2
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 1
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 115 VAC | 115 V -15% / +6%
Electrical power consumption 1 VA | 1 W
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Performance Level, stop 0, up to e
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Number of NC (Normally Closed) Contacts 1
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 121.9 VAC
Rated control voltage at AC 60 Hz, maximum 121.9 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 97.8 VAC
Rated AC voltage for controls, 60 Hz, minimum 97.8 VAC
IP Degree of protection of the installation space IP54
Drop-out delay in case of "emergency stop", maximum 35 ms
Pull-in delay at automatic start, maximum, typically 30 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3