Order No
101178397
Schmersal
Safe Signal Processing
Security Relay and Control Modules
SRB402NE 230V Security Relay and Control Modules
Schmersal SRB402NE 230V features glass-fibre reinforced thermoplastic / ventilated housing material, -25 ... +45 °C ambient temperature, screw terminals, 121 mm depth and snaps onto standard DIN rail to EN 60715 mounting.
Product Description
- • Ağırlık: 550 g
Standards
- • EN IEC 60947-5-3
- • EN IEC 61508
- • EN IEC 62061
- • EN ISO 13849-1
- • EN IEC 60947-5-1
- • EN IEC 60947-5-5
- • EN IEC 60204-1
- • EN IEC 60947-1
Product Features
- • Suitable for the signal processing of outputs with contact sensors
- • Possibility to connect a non-contact end switch or speed reduction switch
- • 2 safety contacts, switch-off level 1;2 safety contacts, switch-off level 2
- • 2 Signalling outputs
Technical Specifications
Depth
121 mm
Mounting
Snaps onto standard DIN rail to EN 60715
General note
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width
45 mm
PFH value
2.00 x 10⁻⁸ /h
EMC rating
EMC-Directive
Height
100 mm
Cable Cross-Section
0.25 mm² ... 2.5 mm²
Voltage type
AC
Shock resistance
30 g / 11 ms
Stop-Category
0
Mission time
20 Year(s)
Net Ağırlık
550 g
Number of LEDs
7
Climatic stress
EN 60068-2-78
Frequency range
50 Hz | 60 Hz
Gross weight
550 g
Category, Stop 0
4
Feedback circuit
Yes
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
Ag-Ni, self-cleaning, positive drive
Pollution degree
2
Min. cable cross-section
0.25 mm²
Operating voltage
230 VAC -15 % / +10 %
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section
2.5 mm²
Ambient Temperature
-25 ... +45 °C
Removable Terminals
Yes
Mechanical life (min.)
10,000,000
Allowed type of cable
solid single-wire | flexible
Note (Wiring diagram)
(H2) = Feedback circuit | Relay outputs: Suitable for 1 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | The control system recognises wire-breakage and earth faults in the monitoring circuit. | The example shows a 1-channel control with contact A for a guard door monitor; of which at least one contact has positive break; with external reset button (R). | The wiring diagram is shown with non-actuated limit switches and in de-energised condition.
Terminal designations
IEC/EN 60947-1
Terminal connection
Screw terminals
Cross-circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-25 °C
Number of safety contacts
4
Maks. Ortam Sıcaklığı
+45 °C
Note (Contact resistance)
in new state
Earth connection detection
Yes
Indicated operating states
Position relay K1 | Internal operating voltage Ui | Position relay K3 | Position relay K5 | Position relay K2
Tightening torque of Clips
0.6 Nm
Number of auxiliary contacts
2
Overvoltage category
III
Contact resistance, maximum
0.1 Ω
Nominal Çalışma Voltajı
230 VAC -15% / + 10% | 230 VAC
Switching capacity, maximum
250 VAC | 2 A | 24 VDC | 8 A
Switching capacity, minimum
10 VDC | 10 mA
Electrical power consumption
6 W | 7.8 VA
Number of signalling outputs
2
Note (application conditions)
Safety sensor | Guard system
Conduction resistance, maximum
40 Ω
Rated impulse withstand voltage (Uimp)
4 kV
Performance Level, stop 0, up to
e
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Pull-in delay at RESET, typically
20 ms
Common Cause Failure (CCF), minimum
65
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Integral system diagnostics, status
Yes
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Number of NC (Normally Closed) Contacts
4
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
IP Degree of protection of the enclosure
IP40
Rated control voltage at AC 50 Hz, maximum
253 VAC
Rated control voltage at AC 60 Hz, maximum
253 VAC
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
IP Degree of protection of clips or terminals
IP20
Rated AC voltage for controls, 50 Hz, minimum
195.5 VAC
Rated AC voltage for controls, 60 Hz, minimum
195.5 VAC
Drop-out delay in case of emergency, typically
20 ms
IP Degree of protection of the installation space
IP54
Drop-out delay in case of power failure, typically
80 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3