Schmersal SRB402NE 230V
Order No 101178397
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB402NE 230V Security Relay and Control Modules

Schmersal SRB402NE 230V features glass-fibre reinforced thermoplastic / ventilated housing material, -25 ... +45 °C ambient temperature, screw terminals, 121 mm depth and snaps onto standard DIN rail to EN 60715 mounting.

Product Description

  • • Ağırlık: 550 g

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 62061
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1
  • • EN IEC 60947-5-5
  • • EN IEC 60204-1
  • • EN IEC 60947-1

Product Features

  • • Suitable for the signal processing of outputs with contact sensors
  • • Possibility to connect a non-contact end switch or speed reduction switch
  • • 2 safety contacts, switch-off level 1;2 safety contacts, switch-off level 2
  • • 2 Signalling outputs

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
PFH value 2.00 x 10⁻⁸ /h
EMC rating EMC-Directive
Height 100 mm
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type AC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 550 g
Number of LEDs 7
Climatic stress EN 60068-2-78
Frequency range 50 Hz | 60 Hz
Gross weight 550 g
Category, Stop 0 4
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material Ag-Ni, self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 230 VAC -15 % / +10 %
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Ambient Temperature -25 ... +45 °C
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) (H2) = Feedback circuit | Relay outputs: Suitable for 1 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | The control system recognises wire-breakage and earth faults in the monitoring circuit. | The example shows a 1-channel control with contact A for a guard door monitor; of which at least one contact has positive break; with external reset button (R). | The wiring diagram is shown with non-actuated limit switches and in de-energised condition.
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Number of safety contacts 4
Maks. Ortam Sıcaklığı +45 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Internal operating voltage Ui | Position relay K3 | Position relay K5 | Position relay K2
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 2
Overvoltage category III
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 230 VAC -15% / + 10% | 230 VAC
Switching capacity, maximum 250 VAC | 2 A | 24 VDC | 8 A
Switching capacity, minimum 10 VDC | 10 mA
Electrical power consumption 6 W | 7.8 VA
Number of signalling outputs 2
Note (application conditions) Safety sensor | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Performance Level, stop 0, up to e
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Pull-in delay at RESET, typically 20 ms
Common Cause Failure (CCF), minimum 65
Current, Utilisation category AC-15 4 A
Current, Utilisation category DC-13 4 A
Integral system diagnostics, status Yes
Voltage, Utilisation category AC-15 230 VAC
Voltage, Utilisation category DC-13 24 VDC
Number of NC (Normally Closed) Contacts 4
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 253 VAC
Rated control voltage at AC 60 Hz, maximum 253 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 195.5 VAC
Rated AC voltage for controls, 60 Hz, minimum 195.5 VAC
Drop-out delay in case of emergency, typically 20 ms
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 80 ms
Pull-in delay at automatic start, maximum, typically 100 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in 3
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3