Order No
151137966
Certificates
cULus
Schmersal
Automation Technology
Position / Limit Switches
T. 064-12Y-R=2X90GR. Position / Limit Switches
Schmersal T. 064-12Y-R=2X90GR. features mechanical working principle, slow action switching principle, grey cast iron / galvanised housing material and IP65 protection class.
Product Description
- • IP: IP65
- • Ağırlık: 3,420 g
- • Sertifika: cULus
Standards
- • EN IEC 60947-5-1
Product Features
- • Metal enclosure
- • 184 mm x 111 mm x 149 mm (basic component)
- • 2 cable entries M 25 x 1.5
- • 3 or 4 Contacts
- • Actuator heads can be repositioned by 4 x 90°
Technical Specifications
Note
All indications including the conductor ferrules.
General note
Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.
Slide form
Sphere
Cable Cross-Section
1.5 mm² ... 4 mm² (All indications including the conductor ferrules.)
Net Ağırlık
3,420 g
Actuating angle
20 °
Bağlantı Tipi
Screw terminals M25
Gross weight
3,420 g
Housing Material
Grey cast iron, galvanised
Contact material
Silver
Latching position
2 x 90°
Min. cable cross-section
1.5 mm²
Sensor length
149 mm
Max. cable cross-section
4 mm²
Wire cross-section
11 AWG
IP protection class
IP65
Ambient Temperature
-30 ... +90 °C | -40 ... +90 °C
Sensor width
156 mm
Conventional thermal current
25 A
Working Principle
mechanical
Switching element
1 NO contact, 2 NC contacts
Switching principle
Slow action
Kontak Açıklığı
2 x 4 mm
Mechanical life (min.)
1,000,000
Sensor height
111 mm
Utilisation category
AC-15
Maks. Sigorta Değeri
16 A gL/gG D-fuse
Min. Actuation Speed
0.1 mm/min
Note (Actuating speed)
Actuating speed with vertical actuating angle to switch axis
Diameter of the Plunger
10 mm
Max. actuating speed
3 m/s
Housing Coating Material
painted
Min. Ortam Sıcaklığı
-30 °C
Note (Switching element)
with double break
Maks. Ortam Sıcaklığı
+90 °C
Utilization Category AC-15
25 A | 400 VAC
Max. switching frequency
1,000 /h
Rated impulse withstand voltage (Uimp)
6 kV
Latching in the limit positions
Yes
B10D Normally-closed contact (NC)
2,000,000
Rated insulation voltage (Uᵢ)
500 V
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2