Note
All indications including the conductor ferrules.
General note
Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.
Slide form
Sphere
Cable Cross-Section
2.5 mm²(All indications including the conductor ferrules.)
Cable entry
3 x M20 x 1,5
Net Ağırlık
255 g
Actuating angle
20 °
Actuating force
14 N
Gross weight
255 g
Housing Material
Light-alloy diecast
Contact material
Silver
Protection class
I
Pollution degree
3
Min. cable cross-section
1.5 mm²
Sensor length
43 mm
Max. cable cross-section
2.5 mm²
Operating current
4,000 mA
Actuation Element
Plunger
IP protection class
IP65
Ambient Temperature
-40 ... +90 °C | -30 ... +90 °C
Sensor width
67 mm
Conventional thermal current
10A
Working Principle
mechanical
Switching element
1 NO contact, 1 NC contacts
Switching principle
Slow action, double break
Kontak Açıklığı
max. 2 x 2.5 mm
Mechanical life (min.)
1,000,000
Sensor height
86 mm
Utilisation category
AC-15
Maks. Sigorta Değeri
20 A gG D-fuse
Min. Actuation Speed
1 mm/min
Note (Actuating speed)
Actuating speed with vertical actuating angle to switch axis
Terminal connection
Screw connection
Diameter of the Plunger
6 mm
Housing Coating Material
chromated
Min. Ortam Sıcaklığı
-30 °C
Note (Delivery capacity)
Not available!
Maks. Ortam Sıcaklığı
+90 °C
Diameter of the ISO-thread
M3
Utilization Category AC-15
400 VAC
Max. switching frequency
500 /h
Nominal Çalışma Voltajı
400 VAC
Wire cross-section, maximum
13 AWG
Rated impulse withstand voltage (Uimp)
6 kV
Rated insulation voltage (Uᵢ)
400 V
Required rated short-circuit current
1,000 A
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
1