Note
All indications including the conductor ferrules.
General note
Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.
Slide form
Sphere
Cable Cross-Section
1.5_2.5_PMAW00000660 | 1.5 mm² ... 2.5 mm²(All indications including the conductor ferrules.)
Cable entry
2 x M20 x 1,5
Net Ağırlık
1,860 g
Actuating angle
20 °
Gross weight
1,860 g
Housing Material
Grey cast iron, galvanised
Contact material
Silver
Min. cable cross-section
1.5 mm²
Sensor length
64 mm
Max. cable cross-section
2.5 mm²
Operating current
4,000 mA
Actuation Element
Plunger
IP protection class
IP65
Ambient Temperature
-40 ... +90 °C | -30 ... +90 °C
Sensor width
118 mm
Conventional thermal current
16 A
Working Principle
mechanical
Switching element
2 NO contact, 2 NC contacts
Switching principle
Slow action, double break
Kontak Açıklığı
max. 2 x 6 mm
Mechanical life (min.)
10,000,000
Sensor height
181 mm
Utilisation category
AC-15
Maks. Sigorta Değeri
16 A gG D-fuse
Min. Actuation Speed
1 mm/min
Note (Actuating speed)
Actuating speed with vertical actuating angle to switch axis
Terminal connection
Screw connection
Diameter of the Plunger
6 mm
Max. actuating speed
1 m/s
Housing Coating Material
painted
Min. Ortam Sıcaklığı
-30 °C
Note (Switching element)
with double break
Maks. Ortam Sıcaklığı
+90 °C
Diameter of the ISO-thread
M4
Utilization Category AC-15
400 VAC | 4 A
Note (Mechanical lifetime)
Contact life: 10 million operations at 1A / 400V, cos ᵠ = 0.4
Max. switching frequency
3,000 /h
Nominal Çalışma Voltajı
400 VAC
Wire cross-section, maximum
13 AWG
Rated impulse withstand voltage (Uimp)
6 kV
Rated insulation voltage (Uᵢ)
400 V
Number of NO (Normally Open) Contacts
2
Number of NC (Normally Closed) Contacts
2