Not
Torx T10 | All indications including the conductor ferrules. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Coding
Bireysel kodlama
Montaj
Screws
Actuator
angled
Kategori
3 | 1
Genel Not
minimum actuating radius on hinged guards in line with the plane of the actuator 200 mm | minimum actuating radius on rotating guard systems via the narrow edge of the actuator 140 mm | The axis of the hinge must be 13 mm above and in a parallel plane to the top surface of the safety switch.
Unlocking
Twist-to-unlock mechanism (auxiliary release)
Traceparts
Yes
Kablo Kesiti
0.75 mm² ... 1 mm² | 0.25 mm² ... 1.5 mm² (All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Strip length
6 mm
Kablo Girişi
1 x M20 x 1,5
Görev Süresi
20 Year(s)
Latching force
30 N | 5 / 30 N
Manual release
Yes
Net Ağırlık
350 g
Power to unlock
Yes
Brüt Ağırlık
350 g
Gövde Malzemesi
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Kontak Malzemesi
Silver
Protection class
II
Kirlenme Derecesi
3
Min. Kablo Kesiti
0.25 mm²
Scope of delivery
The actuator is included in the scope of delivery | Not available as spare part
Sensör Uzunluğu
30 mm
Maks. Kablo Kesiti
1.5 mm²
Çalışma Akımı
2 500 mA
IP Koruma Sınıfı
IP67
Ortam Sıcaklığı
-25 ... +60 °C | -30 ... +60 °C
Performans Seviyesi
d | c
Sensör Genişliği
108 mm
Termal Test Akımı
6 A
Çalışma Prensibi
electromechanical
Anahtarlama Elemanı
Magnet: 2 NC contacts / Actuator: 1 NO contact
Anahtarlama Prensibi
slow action, positive break NC contact
Mekanik Ömür (min.)
1 000 000
Sensör Yüksekliği
100.5 mm
Utilisation category
DC-13
Allowed type of cable
solid single-wire | solid multi-wire | flexible
Magnet switch-on time
100 %
Maks. Sigorta Değeri
6 A gG D-fuse
Note (Manual release)
Manual release from side | For manual release using M5 triangular key, available as accessory
Positive break travel
11 mm
Rated control voltage
24 VAC/DC
Width of the actuator
30 mm
Height of the actuator
12 mm
Interlocking principle
Power to unlock
Length of the actuator
36 mm
Terminal Bağlantısı
Screw terminals
Maks. Aktüasyon Hızı
2 m/s
Tool for the connection
SL
Increased latching force
Yes
Material of the actuator
Stainless steel
Min. Ortam Sıcaklığı
-25 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges
Actuating radius, minimum
140 mm
Güvenlik Kontak Sayısı
2 | 1 / 2 / 3
Maks. Ortam Sıcaklığı
+60 °C
Type of the fixing screws
2x M4
Kullanım Kategorisi AC-15
230 VAC / 4 A / Screw terminals
Kullanım Kategorisi DC-13
24 VDC / 4 A / Screw terminals | 24_4
Yardımcı Kontak Sayısı
1
Aşırı Gerilim Kategorisi
III
Holding force Fmax, maximum
1 300 N
Maks. Anahtarlama Frekansı
1 000 /h
Nominal Çalışma Voltajı
24 VAC | 24 VDC
Wire cross-section, maximum
16 AWG
Wire cross-section, minimum
24 AWG
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Darbe Dayanım Gerilimi (Uimp)
4 kV
Number of actuating directions
2
B10D Normally-open contact (NO)
1 000 000
B10D Normally-closed contact (NC)
2 000 000
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Nominal Yalıtım Gerilimi (Uᵢ)
250 V
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Gerekli Nominal Kısa Devre Akımı
1 000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
12 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
High
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Positive break force per NC contact, minimum
8.5 N
Holding force FZh in accordance with EN ISO 14119
1 000 N
Tightening torque of electrical connection, maximum
0.6 Nm
Tightening torque of electrical connection, minimum
0.4 Nm
Permissible installation altitude above sea level, maximum
2 000 m
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm