| Highlights |
Resistance to salt mist acc. to (IEC 60068-2-11)
Protection rating IP67 all around and IP69k (high pressure and steam cleaning)
EnDra®: maintenance-free and environmentally friendly
Acid- and alkaline resistance
CANopen, Single- and Multiturn
Communication Profile according to CiA 301
Device Profile for encoder CiA 406 V3.2 class C2
Single-/Multiturn (14 bit/40 bit)
Forward-looking technology with 32 Bit processor |
| Product details |
|
| Flange |
clamping flange |
| Housing |
Ø 58 mm
stainless steel, V4A |
| Resolution |
Singleturn Resolution
16,384 steps/360° (14 bit)
Multiturn Resolution
up to 262,144 revolutions (18 bit) with high precision value up to 39 bit. |
| Shaft |
Ø 10 mm
Shaft length: L: 18 mm
Max. Permissible shaft loading radial: 100 N
Max. Permissible shaft loading axial: 100 N |
| Max. operating speed |
3600 rpm |
| Power supply |
10 VDC up to 32 VDC
Current consumption: max. 50 mA
Power consumption: max. 0.5 W |
| Operating temperature |
-20 °C up to +80 °C |
| Storage temperature |
-20 °C up to +80 °C |
| Protection class |
IP67 all around and IP69K. Resistance to salt mist (IEC 60068-2-11) after 672 hours. |
| Advice |
Configuration software
Software download |