Article No
11244232
Product Group
- Inductive distance sensors
- miniature
Detection Distance Max.
0 … 3 mm
Baumer
Inductive proximity sensors
IF08.D03L-Q25.GP1I.7VNU Inductive proximity sensors
Baumer IF08.D03L-Q25.GP1I.7VNU features IO-Link output, 2.5 … 5 mm sensing range, IP 67 protection class, connector connection and -20 … +70 °C operating temperature.
Technical Specifications
Article No
11244232
Product Group
- Inductive distance sensors
- miniature
Housing
- 8 mm x 24.6 mm
- stainless steel
- Linearized
- Quasi-flush
Detection Distance Max.
0 … 3 mm
Features
- IO-Link
- Connector
- -20 … +70 °C
- IP 67
Product Description
- Distance measuring
- 0 … 3 mm
- PNP / push-pull
- IO-Link
- flylead connector M8
- -20 … 70 °C
- IP 67
Detailed Technical Data
General data
Type
Distance measurement
Adjustment
IO-Link
Special type
Linearized
Teach
Single point, Two point, Window
Hysteresis
< 99 % (adjustable)
Mounting type
Quasi-flush
Resolution
< 0.005 mm (High Accuracy Mode)
Temperature drift
- ± 2 % (Full Scale: S = 0 ... 2 mm)
- ± 6 % (Full Scale: S = 0 ... 3 mm)
Measuring distance Sd
0 … 3 mm
Linearity error
- ± 10 µm (S = 0 ... 2 mm)
- ± 90 µm (S = 0 ... 3 mm)
Repeatability accuracy
0.01 mm
Mechanical Data
Dimension
8 mm
Design
Rectangle
Housing length
24.6 mm
Max. tightening torque
0.8 Nm
Housing material
Stainless steel
Connection types
Flylead connector PUR M8, L=200 mm
Material (detection surface)
PBT
Electrical Data
Baud rate
230.4 kBaud (COM 3)
Output current
50 mA
Output circuit
- PNP
- Push-pull
- IO-Link
Switching frequency
1.25 kHz
Short-circuit protection
Yes
Reverse polarity protection
Yes
Voltage supply range +Vs
8 … 30 VDC
Max. current consumption (no load)
15 mA
Response time (factory characteristic)
< 1 ms
Ambient conditions
Protection class
IP 67
Operating temperature
-20 … +70 °C
Communication interface
Interface
IO-Link V1.1
Additional data
- Distance
- Frequency
- Operating cycles
- Operating hours
- Boot cycles
- Operating voltage
- Device temperature
- Histograms
Baud rate
230.4 kBaud (COM 3)
Cycle time
≥ 0.6 ms
IO-Link port type
Class A
Process data structure
- Bit 0 = SSC1 (distance)
- Bit 1 = SSC2 (distance)
- Bit 3 = alarm
- Bit 4 = SSC3 (frequency)
- Bit 5 = SSC4 (counter)
- Bit 16-31 = 16 Bit measurement
Process data length
32 Bit
Adjustable parameters
- Measuring range
- Switching point
- Switching hysteresis
- Measured value filtering
- Time filters
- Output logic
- Output circuit
- Counter
- Deactivate the sensor element
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_Ixxx_08_ML_DoC_81164079.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11244232