Article No
11193949
Product Group
Inductive distance sensors
Detection Distance Max.
0 … 10 mm
Baumer
Inductive proximity sensors
IR18.D10L-F60.GP1I.7BF Inductive proximity sensors
Baumer IR18.D10L-F60.GP1I.7BF features IO-Link output, 5 … 10 mm sensing range, IP 67 protection class, connector connection and -25 … +75 °C operating temperature.
Technical Specifications
Article No
11193949
Product Group
Inductive distance sensors
Housing
- 18 mm x 60 mm
- Metal
- Linearized
- Gömülü
Detection Distance Max.
0 … 10 mm
Features
- IO-Link
- Connector
- -25 … +75 °C
- IP 67
Product Description
- distance measuring
- 0 … 10 mm
- push-pull
- IO-Link
- connector M12
- -25 … 75 °C
- IP 67
Detailed Technical Data
General data
Type
Distance measurement
Adjustment
IO-Link
Special type
Linearized
Teach
Single point, Two point, Window
Hysteresis
< 99 % (adjustable)
Mounting type
Flush
Resolution
< 0.005 mm (High Accuracy Mode)
Temperature drift
± 3 % (Full scale)
Measuring distance Sd
0 … 10 mm
Linearity error
- ± 40 µm (S = 0 ... 8 mm)
- ± 160 µm (S = 0 ... 10 mm)
Output indicator
Yellow LED
Power-on indicator
Green LED
Repeatability accuracy
0.015 mm
Mechanical Data
Dimension
18 mm
Design
Cylindrical gear
Housing length
60 mm
Max. tightening torque
40 Nm
Housing material
Nickel-plated brass
Connection types
M12 Connector
Material (detection surface)
PBT
Electrical Data
Baud rate
230.4 kBaud (COM 3)
Output current
100 mA
Output circuit
- Push-pull
- IO-Link
Switching frequency
800 Hz
Short-circuit protection
Yes
Reverse polarity protection
Yes
Voltage supply range +Vs
8 … 36 VDC
Max. current consumption (no load)
15 mA
Response time (factory characteristic)
< 1 ms
Ambient conditions
Protection class
IP 67
Operating temperature
-25 … +75 °C
Communication interface
Interface
IO-Link V1.1
Additional data
- Distance
- Frequency
- Operating cycles
- Operating hours
- Boot cycles
- Operating voltage
- Device temperature
- Histograms
Baud rate
230.4 kBaud (COM 3)
Cycle time
≥ 0.6 ms
IO-Link port type
Class A
Process data structure
- Bit 0 = SSC1 (distance)
- Bit 1 = SSC2 (distance)
- Bit 3 = alarm
- Bit 4 = SSC3 (frequency)
- Bit 5 = SSC4 (counter)
- Bit 16-31 = 16 Bit measurement
Process data length
32 Bit
Adjustable parameters
- Measuring range
- Switching point
- Switching hysteresis
- Measured value filtering
- Time filters
- LED status indicators
- Output logic
- Output circuit
- Counter
- Deactivate the sensor element
- Find Me function
Documents
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11193949
open_in_new Open