AZM 161SK-12/12IA-024-B1
Order No 103053480
Certificates IFA, cULus, CCC
Schmersal Safe Switching and Monitoring Solenoid Interlocks

AZM 161SK-12/12IA-024-B1 Solenoid Interlocks

AZM 161SK-12/12IA-024-B1 — Schmersal Solenoid Interlocks. Key specifications: Working Principle: electromechanical; Switching principle: slow action, positive break NC contact; IP protection class: IP67; Ambient Temperature: -30 ... +60 °C | -25 ... +60 °C; Terminal connection: Screw terminals. Article number: 103053480. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Sertifika: IFA, cULus, CCC

Standards

  • • EN ISO 13849-1
  • • EN ISO 14119
  • • EN IEC 60947-5-1
  • • BG-GS-ET-19

Product Features

  • • Compact design
  • • Interlock with protection against incorrect locking.
  • • Individual coding
  • • Coding level "High" according to ISO 14119
  • • Double-insulated
  • • High holding force
  • • Long life
  • • Particularly suitable for sliding doors

Technical Specifications

Note All indications including the conductor ferrules. | Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Coding Individual coding
Mounting Screws
Category 3 | 1
General note minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm | The axis of the hinge must be 5 mm above and in a parallel plane to the top surface of the safety switch. | The actuator is not available separately. | minimum actuating radius on hinged guards in line with the plane of the actuator 150 mm
Unlocking Twist-to-unlock mechanism (auxiliary release)
Cable Cross-Section 0.25 mm² ... 1.5 mm²(All indications including the conductor ferrules.) | 0.25 mm² ... 0.75 mm² (All indications including the conductor ferrules.)
Please note: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Strip length 7 mm
Cable entry 4 x M16 x 1,5
Power to lock Yes
Mission time 20 Year(s)
Latching force 5 N | 5 / 30 N
Manual release Yes
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material Silver
Protection class II
Min. cable cross-section 0.25 mm²
Scope of delivery The actuator is included in the scope of delivery | Slot sealing plugs | Not available as spare part
Sensor length 30 mm
Max. cable cross-section 1.5 mm²
IP protection class IP67
Ambient Temperature -30 ... +60 °C | -25 ... +60 °C
Performance level c | d
Sensor width 130 mm
Conventional thermal current 6 A
Working Principle electromechanical
Switching element Magnet: 1 NO contact, 2 NC contacts / Actuator: 1 NO contact, 2 NC contacts
Switching principle slow action, positive break NC contact
Mechanical life (min.) 1,000,000
Sensor height 90 mm
Allowed type of cable solid single-wire | solid multi-wire | flexible
Magnet switch-on time 100 %
Maks. Sigorta Değeri 6 A gG D-fuse to DIN EN 60269-1
Positive break travel 10 mm
Rated control voltage 24 VAC/DC
Terminal connection Screw terminals
Type of the screw head Flat head screw
Max. actuating speed 2 m/s
Tool for the connection SL 0.6 x 3.5 mm
Material of the actuator Stainless steel
Min. Ortam Sıcaklığı -25 °C | -30 °C
Note (Relative humidity) non-condensing | non-icing
Actuating radius, minimum 150 mm
Number of safety contacts 4 / 5 | 4
Maks. Ortam Sıcaklığı +60 °C
Type of the fixing screws 3x M5
Utilization Category DC-13 24 VDC / 4 A
Number of auxiliary contacts 1 / 2 | 2
Holding force Fmax, maximum 2,600 N
Max. switching frequency 1,000 /h
Test pulse duration, maximum 5 ms
Test pulse interval, minimum 50 ms
Note (application conditions) removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp) 4 kV
Number of actuating directions 3
B10D Normally-open contact (NO) 1,000,000
B10D Normally-closed contact (NC) 2,000,000
Depolama / Taşıma Sıcaklığı -30 ... +85 °C
Rated insulation voltage (Uᵢ) 250 VAC
Current, Utilisation category AC-15 4 A
Current, Utilisation category DC-13 2.5 A
Required rated short-circuit current 1,000 A
Voltage, Utilisation category AC-15 230 VAC
Voltage, Utilisation category DC-13 24 VDC
Electrical power consumption, maximum 10 W
Protection class (Operating resource) 2
Coding level according to EN ISO 14119 High
Actuating play in direction of actuation 5.5 mm
Colour of the upper part of the enclosure Black
Colour of the bottom part of the enclosure black
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Positive break force per NC contact, minimum 10 N
Holding force FZh in accordance with EN ISO 14119 2,000 N
Tightening torque of electrical connection, maximum 0.5 Nm
Tightening torque of electrical connection, minimum 0.4 Nm
Permissible installation altitude above sea level, maximum 2,000 m
Tightening torque of the fastening screws for the housing cover 0.6 Nm

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.