AZM 170-11ZRI B6R-2197 24VAC/DC
Order No 101146835
Certificates cULus, CCC cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

AZM 170-11ZRI B6R-2197 24VAC/DC

AZM 170-11ZRI B6R-2197 24VAC/DC — Schmersal product. Key specifications: Working Principle: electromechanical; Switching principle: slow action, positive break NC contact; Switching element: 1 NO contact, 1 NC contacts; IP protection class: IP67; Ambient Temperature: -30 ... +60 °C | -25 ... +60 °C. Article number: 101146835. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 308 g
  • • Sertifika: cULus, CCC cULus

Standards

  • • EN ISO 13849-1
  • • EN IEC 60947-5-1
  • • BG-GS-ET-19
  • • EN ISO 14119

Product Features

  • • Manual release from side
  • • IDC method of termination
  • • Individual coding
  • • Interlock with protection against incorrect locking.
  • • Long life
  • • right-hand model
  • • For very smal actuating radii in line with or at 90° to the plane of the actuator

Technical Specifications

Note Torx T10 | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Coding Individual coding
Mounting Screws
CADENAS Yes
Actuator flexible | right-hand version
Category 3 | 1
General note This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules
Unlocking Twist-to-unlock mechanism (auxiliary release)
Traceparts Yes
Cable Cross-Section 0.75 mm² ... 1 mm²
Please note: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Cable entry 1 x M20 x 1,5
Mission time 20 Year(s)
Latching force 30 N
Manual release Yes
Net Ağırlık 308 g
Power to unlock Yes
Gross weight 308 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material Silver
Protection class II
Pollution degree 3
Min. cable cross-section 0.75 mm²
Scope of delivery The actuator is included in the scope of delivery | Not available as spare part
Sensor length 30 mm
Max. cable cross-section 1 mm²
Operating current 2,500 mA
IP protection class IP67
Ambient Temperature -30 ... +60 °C | -25 ... +60 °C
Performance level d | c
Sensor width 108 mm
Conventional thermal current 6 A
Working Principle electromechanical
Switching element 1 NO contact, 1 NC contacts
Switching principle slow action, positive break NC contact
Mechanical life (min.) 1,000,000
Sensor height 84 mm
Utilisation category AC-15 | DC-13
Allowed type of cable solid single-wire | solid multi-wire | flexible
Magnet switch-on time 100 %
Maks. Sigorta Değeri 6 A gG D-fuse
Note (Manual release) Manual release from side | For manual release using M5 triangular key, available as accessory
Positive break travel 11 mm
Rated control voltage 24 VAC/DC
Width of the actuator 30 mm
Height of the actuator 32 mm
Interlocking principle Power to unlock
Length of the actuator 35 mm
Terminal connection IDC method of termination
Max. actuating speed 2 m/s
Increased latching force Yes
Material of the actuator Stainless steel
Min. Ortam Sıcaklığı -25 °C
Note (Relative humidity) non-condensing | non-icing
Note (Switching element) Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges
Actuating radius, minimum 50 mm
Number of safety contacts 1 / 2 / 3 | 1
Maks. Ortam Sıcaklığı +60 °C
Type of the fixing screws 2x M4
Utilization Category AC-15 230 VAC / 4 A / Screw terminals | 230_4
Utilization Category DC-13 24 VDC / 4 A / Screw terminals | 24_4 | 24 VDC / 4 A
Number of auxiliary contacts 1
Overvoltage category III
Holding force Fmax, maximum 1,300 N
Max. switching frequency 1,000 /h
Nominal Çalışma Voltajı 24 VAC | 24 VDC
Wire cross-section, maximum 20 AWG
Wire cross-section, minimum 18 AWG
Test pulse duration, maximum 5 ms
Test pulse interval, minimum 50 ms
Note (application conditions) removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp) 4 kV
Number of actuating directions 2
B10D Normally-open contact (NO) 1,000,000
B10D Normally-closed contact (NC) 2,000,000
Depolama / Taşıma Sıcaklığı -25 ... +85 °C | -40 ... +85 °C
Rated insulation voltage (Uᵢ) 250 V
Current, Utilisation category AC-15 4 A
Current, Utilisation category DC-13 4 A
Required rated short-circuit current 1,000 A
Voltage, Utilisation category AC-15 230 VAC
Voltage, Utilisation category DC-13 24 VDC
Electrical power consumption, maximum 12 W
Protection class (Operating resource) 2
Coding level according to EN ISO 14119 High
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
Positive break force per NC contact, minimum 8.5 N
Holding force FZh in accordance with EN ISO 14119 1,000 N
Permissible installation altitude above sea level, maximum 2,000 m
Tightening torque of the fastening screws for the housing cover, maximum 1 Nm
Tightening torque of the fastening screws for the housing cover, minimum 0.7 Nm