Note
Torx T10 | All indications including the conductor ferrules.
EPLAN
Yes
Coding
Universal coding
CADENAS
Yes
Category
2 | 4
General note
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
PFD value
8.90 x 10⁻⁴ | 1.60 x 10⁻⁴
PFH value
1.00 x 10⁻⁸ /h | 1.90 x 10⁻⁹ /h
Cable Cross-Section
0.25 mm² ... 1.5 mm²(All indications including the conductor ferrules.) | 0.25 mm² ... 0.75 mm² (All indications including the conductor ferrules.)
Voltage type
DC
Shock resistance
30 g / 11 ms
Cable entry
1 x M20 x 1,5
Series-wiring
Yes
Mission time
20 Year(s)
Latching force
30 N
Manual release
Yes
Net Ağırlık
566 g
Bağlantı Tipi
Spring pulley connection
Connection type
Screw terminals, Connector M12, 8-pole, Spring pulley connection
Power to unlock
Yes
Gross weight
566 g
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
III
Safety functions
Yes
Pollution degree
3
Min. cable cross-section
0.25 mm²
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Scope of delivery
Actuator must be ordered separately. | Triangular key for AZM 201
Sensor length
50 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
Max. cable cross-section
1.5 mm²
Wire cross-section
23 ... 15 AWG
Wiring capacitance
50 nF
Operating current
1,200 mA | 50 mA | 150 mA
Frequency band RFID
125 kHz
IP protection class
IP66 | IP67
Ambient Temperature
-30 ... +60 °C | -25 ... +60 °C
Performance level
d | e
Sensor width
40 mm
Working Principle
RFID
Degree of protection
IP66, IP67
Mechanical life (min.)
1,000,000
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
220 mm
Switching thresholds
-3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High) | −3 V … 5 V (Low)15 V … 30 V (High) | -3 V … 5 V (Low)15 V … 30 V (High)
Allowed type of cable
solid single-wire, solid multi-wire, flexible | solid single-wire | solid multi-wire | flexible
Magnet switch-on time
100 %
Electrical fuse rating
short-circuit proof, p-type
Cross-circuit detection
Yes
Max. actuating speed
0.2 m/s
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-30 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
Note (holding force FZh)
1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Voltage drop Ud, maximum
2 V | 4 V
Duration of risk, maximum
200 ms
Maks. Ortam Sıcaklığı
+60 °C
Note (holding force Fmax)
1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Recommendation (actuator)
AZ/AZM201-B1 | AZ/AZM201-B30
Type of the fixing screws
2x M6
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05
Operating voltage, maximum
26.4 VDC
Operating voltage, minimum
20.4 VDC
Relative humidity, maximum
93 %
Time to readiness, maximum
4,000 ms
Overvoltage category
3 | III
Current consumption at 24 V
5 mA | 10 mA
Designation, Magnet control
IN
Designation, Safety outputs
Y1 and Y2
Holding force Fmax, maximum
2,600 N
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Wire cross-section, maximum
15 AWG
Wire cross-section, minimum
23 AWG
Solenoid interlock monitored
Yes
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
5 ms | 1 ms | 0.5 ms
Test pulse interval, minimum
40 ms | 100 ms
Test pulse interval, typical
1,000 ms
Rated impulse withstand voltage (Uimp)
0.8 kV
Fuse rating to UL 508, maximum
4 A
Classification ZVEI CB24I, Sink
C1 | C0 | C2
Designation, Diagnostic outputs
OUT
Length of sensor chain, maximum
200 m
Transmitter output RFID, maximum
-6 dBm
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Classification ZVEI CB24I, Source
C3 | C1 | C2
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C | -30 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
50 mA
Number of digital fail-safe inputs
2
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-13
24 VDC
External wire and device fuse rating
4A when used in accordance with UL 508 (Spring pulley connection) | 4A when used in accordance with UL 508 | 2 A gG (Connector M12, 8-pole)4 A gG (Screw terminals)4 A gG (Spring pulley connection)
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
Low | I1 variant: HighI2 variant: HighStandard coded variant: Low
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Current consumption with magnet ON, peak
700 mA / 100 ms
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-30 °C
Current consumption with magnet ON, average
200 mA
Tightening torque of the fixing screws, maximum
8 Nm
Holding force FZh in accordance with EN ISO 14119
2,000 N
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
2 | 3
Tightening torque of the fastening screws for the housing cover
0.7 ... 1 Nm (Torx T10)
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
1.5 ms
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm