PIN 1
AS-Interface +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)
Coding
Individual coding, multiple teaching
CADENAS
Yes
Category
4
Latching
Yes
General note
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
PFD value
2.34 x 10⁻⁴
PFH value
1.34 x 10⁻⁹ /h
Fuse rating
4 A
AS-i Profile
S-7.B.F.E
AS-i Version
V 3.0
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Manual release
Yes
Net Ağırlık
595 g
Bağlantı Tipi
Connector plug M12, 4-pole, (A-coding)
Power to unlock
Yes
Gross weight
595 g
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
III
Safety functions
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Scope of delivery
Actuator must be ordered separately.
Sensor length
120 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Specification
Safety-Slave
Current consumption
300 mA
Frequency band RFID
125 kHz
IP protection class
IP66 | IP69 | IP67
Note voltage AUX DC
stabilised PELV power supply
Ambient Temperature
+0 ... +60 °C
Performance level
e
Sensor width
87.5 mm
Working Principle
RFID
Mechanical life (min.)
1,000,000
Sensor height
35 mm
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
Magnet switch-on time
100 %
AS-i Device protection
Internal short-circuit proof
Reaction time, maximum
120 ms
AS-i Parameter bits, P0
Safety guard closed and can be locked
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
Auxiliary voltage in
AS-i Parameter bits, P3
Internal device error (FID)
Min. Ortam Sıcaklığı
+0 °C
Note (Delivery capacity)
Not available!
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity)
non-condensing | non-icing
Switch distance, typical
2 mm
AS-i Input module address
0
Duration of risk, maximum
200 ms
Maks. Ortam Sıcaklığı
+60 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
AZ/AZM300-B1
Type of the fixing screws
2x M6
Note (Mechanical lifetime)
When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Relative humidity, maximum
93 %
Time to readiness, maximum
5,000 ms
Overvoltage category
3 | III
Holding force Fmax, maximum
1,500 N
Nominal Çalışma Voltajı
24 VDC -15% / +10% (stabilised PELV) | 24 VDC | 18 ... 31.6 VDC (Protection against polarity reversal)
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
Solenoid interlock monitored
Yes
Note (AS-i Operating voltage)
Protection against polarity reversal
Rated impulse withstand voltage (Uimp)
0.8 kV
Number of actuating directions
3
AS-i Operating voltage, minimum
18 VDC
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Transmitter output RFID, maximum
-6 dBm
AS-i Current consumption, maximum
100 mA
Depolama / Taşıma Sıcaklığı
-10 ... +90 °C
Rated insulation voltage (Uᵢ)
32 VDC
AS-i Operating voltage AS-i maximum
31.6 VDC
Assured switching distance "ON" Sao
1 mm
Integral system diagnostics, status
Yes
Assured switching distance "OFF" Sar
20 mm
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
High
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Tightening torque of the fixing screws
6 ... 7 Nm
Note (LED switching conditions display)
(2) LED yellow: Device condition (Enabling status) | (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active | (3) LED red: Internal device error
Storage and transport temperature, maximum
+90 °C
Storage and transport temperature, minimum
-10 °C
Tightening torque of the fixing screws, maximum
7 Nm
Tightening torque of the fixing screws, minimum
6 Nm
Holding force FZh in accordance with EN ISO 14119
1,150 N
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
3
Angular misalignment between solenoid interlock and actuator, maximum
2 °