BDF200-ST1-AS-NHK-LT-LT-LT-2875
Order No 103038634
Certificates cULus cULus, ASi-SaW
Schmersal Safe Switching and Monitoring AS-i Emniyet Sistemi

BDF200-ST1-AS-NHK-LT-LT-LT-2875 AS-i Emniyet Sistemi

BDF200-ST1-AS-NHK-LT-LT-LT-2875 — Schmersal AS-i Emniyet Sistemi. Key specifications: IP protection class: IP65; Ambient Temperature: -25 ... +65 °C | -40 ... +100 °C; Depth: 233.5 mm; PIN 1: AS-Interface +; PIN 2: n.c.. Article number: 103038634. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 280 g
  • • Sertifika: cULus cULus, ASi-SaW

Standards

  • • EN IEC 61508
  • • EN ISO 13850
  • • EN IEC 60947-5-1
  • • EN ISO 13849-1
  • • EN IEC 62026-2

Product Features

  • • Integrated AS-Interface
  • • with connector plug M12 bottom
  • • Pos 1: E-STOP with protective collar
  • • Pos 2: illuminated pushbutton with changeable colors
  • • Pos 3: illuminated pushbutton with changeable colors
  • • Pos 4: illuminated pushbutton with changeable colors
  • • slender shock-proof thermoplastic enclosure
  • • to be installed at an ergonomic favourable position
  • • to be fitted to commercial-off-the-shelf aluminium profiles

Technical Specifications

Note Both AS-i slaves can be enabled and disabled through the integrated DIP switch. The addressing must take place via the M12 connector.
Depth 233.5 mm
PIN 1 AS-Interface +
PIN 2 n.c.
PIN 3 AS-Interface -
PIN 4 n.c.
Mounting interior mounting holes
Category 4
Width 40 mm
PFH value 1.40 x 10⁻⁸ /h
Height 69 mm
Shock resistance 15 g / 11 ms
Mission time 20 Year(s)
Indicator lamp No
Net Ağırlık 280 g
Bağlantı Tipi Connector plug M12, 4-pole, (A-coding)
Climatic stress DIN EN 60068
Gross weight 280 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Note (PFH-value) up to max. 5,000 switching cycles/year
Protection class II
Pollution degree 3
Vibration resistance 10 … 150 Hz, amplitude 0.35 mm / 5 g
Connector position Bottom
IP protection class IP65
Ambient Temperature -25 ... +65 °C | -40 ... +100 °C
Performance level e
Note (Ordering data) Notice: see ordering code
AS-i Device protection Internal short-circuit proof
Reaction time, maximum 100 ms
Traceparts, product ID 69-13072010-095143
AS-i Profile (A/B Slave) S-7.A.7.F
AS-i Version (A/B Slave) V 3.0
Min. Ortam Sıcaklığı -25 °C
AS-i Input module address 0
Maks. Ortam Sıcaklığı +65 °C
Type of the fixing screws 2x M5
Positions used, position 1 Emergency stop, with protective collar
Positions used, position 2 Illuminated pushbutton, color exchangeable
Positions used, position 3 Illuminated pushbutton; color exchangeable
Positions used, position 4 Illuminated pushbutton, color exchangeable
AS-i Profile (Safety-Slave) S-7.B.F.F
AS-i Version (Safety-Slave) V 3.0
Overvoltage category III
Nominal Çalışma Voltajı 18 ... 31.6 VDC (Protection against polarity reversal)
Note (AS-i Parameter bits) Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input, DI 0 (A/B Slave) Command device Position 4
AS-i Input, DI 1 (A/B Slave) Command device Position 3
AS-i Input, DI 2 (A/B Slave) Command device Position 2
AS-i Input, DI 3 (A/B Slave) Command device Position 2
AS-i Output, DO 0 (A/B Slave) Illuminated signal position 4
AS-i Output, DO 1 (A/B Slave) Illuminated signal position 3
AS-i Output, DO 2 (A/B Slave) Illuminated signal position 2
AS-i Output, DO 3 (A/B Slave) No Function
Note (AS-i Operating voltage) Protection against polarity reversal
Rated impulse withstand voltage (Uimp) 0.8 kV
AS-i Operating voltage, minimum 18 VDC
AS-i Output, DO 0 (Safety-Slave) Indicator lamp G24 red
AS-i Output, DO 1 (Safety-Slave) Indicator lamp G24 green
AS-i Output, DO 2 (Safety-Slave) No Function
AS-i Output, DO 3 (Safety-Slave) No Function
Note (AS-i Input module address) Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
AS-i Current consumption, maximum 150 mA
Depolama / Taşıma Sıcaklığı -40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ) 32 VDC
AS-i Operating voltage AS-i maximum 31.6 VDC
AS-i Input, Channel 1 (Safety-Slave) Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2 (Safety-Slave) Data bits DI 2 / DI 3 = dynamic code transmission
Mechanical lifetime, Command devices 1,000,000
Protection class (Operating resource) 2
Mechanical lifetime, Emergency-Stop button 100,000
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
AS-i AS-i Parameter bits (A/B Slave), P0 ... P3 No function
AS-i AS-i Parameter bits (Safety-Slave), P0 ... P3 No function
Permissible installation altitude above sea level, maximum 2,000 m
Safety Integrity Level (SIL), suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3