Coding
Yes
General note
The contact configuration for versions with or without LED is identical. | Contact symbols shown for the closed condition of the guard device.
Cable type
LiYY
Active area
lateral
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Net Ağırlık
205 g
Bağlantı Tipi
cable
Length of cable
1 m
Gross weight
205 g
Housing Material
Stainless steel (V4A)
Scope of delivery
Actuator must be ordered separately.
Sensor length
14 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Wire cross-section
0.25 mm² | 23 AWG
Actuation Element
Magnet
Direction of motion
Head-on to the active surface
IP protection class
IP69 | IP67 | IP65
Ambient Temperature
-25 ... +80 °C | -25 ... +100 °C
Sensor width
88 mm
Working Principle
Magnetic drive
Switching element
1 NO contact, 2 NC contacts
Switching principle
Reed contacts, Non-contact principle
Sensor height
27 mm
Note (Wiring diagram)
Contact S21-S22 must be integrated in the safety circuit.
Number of cable wires
6
Min. Ortam Sıcaklığı
-25 °C
Maks. Ortam Sıcaklığı
+100 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
BPS 40S-1-T | BPS 40S-1-C-T | BPS 40S-2-T | BPS 40S-2-C-T
Mechanical Mounting Conditions
not flush
Switching current, maximum
0.25 A
Switching voltage, maximum
100 VAC | 100 VDC
Switching capacity, maximum
3 W
Material of the Cable mantle
PVC
Prerequisite evaluation unit
Yes
Switching frequency, maximum
5 Hz
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC
Depolama / Taşıma Sıcaklığı
-25 ... +80 °C | -25 ... +100 °C
Assured switching distance "ON" Sao
8 mm
Assured switching distance "OFF" Sar
18 mm
Number of NO (Normally Open) Contacts
1
Concealed, threaded holes on the back
No
Number of NC (Normally Closed) Contacts
2
Coding level according to EN ISO 14119
Low
Storage and transport temperature, maximum
+100 °C
Storage and transport temperature, minimum
-25 °C
B10D- Value Normally-closed contact/Normally open contact (NC/NO)
25,000,000