Coding
Individual coding, multiple teaching
Mounting
2 x M5, Cylinder head screw
CADENAS
Yes
Category
4
PFD value
1.50 x 10⁻⁵
PFH value
6.30 x 10⁻¹¹ /h
Cascadable
Yes
Traceparts
Yes
Active area
front side | Glass-fibre, reinforced thermoplastic | cover-side | lateral
Voltage type
DC
Shock resistance
30 g / 11 ms
Series-wiring
Yes
Mission time
20 Year(s)
Number of LEDs
2
Latching magnet
Yes
Length of cable
15 m
Sensor topology
Sensor for series wiring
Actuating panels
from head | front side | rear
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Safety functions
Yes
Diagnostic output
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 %
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
91 mm
Operating current
2,100 mA | 50 mA
IP protection class
IP67 | IP65
Ambient Temperature
-20_+60 | -20 ... +60 °C
Performance level
e
Sensor width
52 mm
Working Principle
RFID
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
30 mm
Interfering radiation
IEC 61000-6-4
Reaction time, maximum
100 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Manufacturer declaration
ATEX Zone 2 and 22
Min. Ortam Sıcaklığı
-20 °C
Note (Relative humidity)
non-condensing | non-icing
Switch distance, typical
15 mm
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
200 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+60 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
RST16-1-R
Design of control elements
p-type
Utilization Category DC-13
24 VDC / 0.05 A | 24_0.05
Mechanical Mounting Conditions
not flush
Operating current, minimum
0.5 mA
Relative humidity, maximum
93 %
Time to readiness, maximum
2,000 ms
Utilisation category DC-12
24_1 | 24 VDC / 0.05 A | 24 VDC / 1 A | 24_0.05
Overvoltage category
3 | III
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Switching frequency, maximum
1 Hz
Explosion protection category
3G | 3D
Recommended safety switchgear
SRB200EXi | SRB-E-301ST | SRB-E-201LC | SRB101EXi | PROTECT PSC1
Rated impulse withstand voltage (Uimp)
0.8 kV
Manufacturer declaration, zone
22 | 2
Explosion protection designation
D II 3D Ex tc IIIC T90°C Dc X
Rated operating voltage, maximum
26.4 VDC
Rated operating voltage, minimum
20.4 VDC
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-7 | EN 60079-31
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Assured switching distance "ON" Sao
5 mm
Current, Utilisation category DC-12
0.05 A | 1 A
Current, Utilisation category DC-13
0.05 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof, p-type
Assured switching distance "OFF" Sar
30 mm
Coding level according to EN ISO 14119
High
Tightening torque of the fixing screws
2 Nm
Note (LED switching conditions display)
LED green: Supply voltage | Multi-coloured LED: Green, Red | LED red: Fault | LED yellow: Operating condition
Current consumption of the safety inputs
5 mA
Hysteresis (Switching distance), maximum
2 mm
Rated operating current (safety outputs)
1,000 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
1 A
Number of semi-conductor outputs with signaling function
1
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
3