Depth
118 mm
EPLAN
Yes
Mounting
Snaps onto standard DIN rail to EN 60715
Notice
Valid for dual channel and 60% relay load
Category
2 | 4
Width
52.5 mm
PFH value
1.78 x 10⁻⁸ /h
EMC rating
EMC-Directive
Height
100 mm
Demand rate
high or continuous
Start input
Yes
Cable Cross-Section
0.25 mm² ... 2.5 mm²
Voltage type
DC
Shock resistance
30 g / 11 ms
Start-up test
Yes
Mission time
20 Year(s)
Net Ağırlık
300 g
Bağlantı Tipi
rigid or flexible
Climatic stress
EN 60068-2-2 | EN 60068-2-1 | EN 61496
Gross weight
300 g
Feedback circuit
Yes
Housing Material
Polyamide / V0
Contact material
Tin
Pollution degree
2
Min. cable cross-section
0.25 mm²
Operating voltage
12 VDC -10 % / +10 % | 24 V
Relative humidity
15 ... 90 %
Vibration resistance
10 … 57 Hz, amplitude 0.75 mm
Max. cable cross-section
2.5 mm²
Operating current
100 mA
IP protection class
IP20
Ambient Temperature
-25 ... +55 °C
Performance level
e | d
Removable Terminals
Yes
Mechanical life (min.)
10,000,000
Reset edge detection
Yes
Switching thresholds
18 V … 28.8 V | -3 V … 2 V (LOW)
Terminal designations
IEC/EN 60947-1 | IEC 61131-2
Terminal connection
Removable screw terminals
Cross-circuit detection
Yes
Input resistance at GND
10,000 Ω
Short circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing
Maks. Ortam Sıcaklığı
+55 °C
Design of control elements
short-circuit proof, p-type (Q2 und Q3) | Limited short-circuit protection, p-type | short-circuit proof, p-type / n-type (Q0/0N and Q1/1N)
Earth connection detection
Yes
Operating voltage, maximum
26.4 VDC
Operating voltage, minimum
21.6 VDC
Relative humidity, maximum
90 %
Relative humidity, minimum
15 %
Tightening torque of Clips
0.6 Nm
Overvoltage category
3 | III
Current consumption at 24 V
6 mA
Leakage current Ir, maximum
2 mA
Nominal Çalışma Voltajı
12 VDC
Number of signalling outputs
4
Switching frequency, maximum
0.1 Hz
Note (application conditions)
Safety light curtain | Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Diagnostic Coverage (DC) Level
99 %
Hardware fault tolerance (HFT)
1
Electrical fuse rating, maximum
3 A
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C
Current, Utilisation category AC-1
4 A
Current, Utilisation category DC-1
4 A
Integrated Display, Supply Voltage
Yes
No-load supply current I0, typical
500 mA
Number of digital fail-safe inputs
14
Voltage, Utilisation category AC-1
250 VAC
Voltage, Utilisation category DC-1
24 VDC
Common Cause Failure (CCF), minimum
65
Current consumption at 24V, maximum
500 mA
Current, Utilisation category AC-15
3 A
Current, Utilisation category DC-13
4 A
Required rated short-circuit current
1,000 A
Integral system diagnostics, status
Yes
Note (Electrical data, Fuse rating)
slow blow
Number of fail-safe analogue inputs
2
Number of fail-safe digital outputs
4
Number of relay outputs (1-channel)
2
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
4 A gL/gG D-fuse
Safe Failure Fraction (SFF), minimum
90
Number of digital fail-safe in-/outputs
4
Rated operating current (safety outputs)
700 mA
Storage and transport temperature, maximum
+75 °C
Storage and transport temperature, minimum
-25 °C
Number of pulse outputs (test pulse output)
3
IP Degree of protection of the installation space
IP54
Safety Integrity Level (SIL), suitable for applications in
2 | 3