PROTECT-SELECT-SK
Order No 101218030
Certificates TÜV, cULus, CCC cULus TÜV
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

PROTECT-SELECT-SK

PROTECT-SELECT-SK — Schmersal product. Key specifications: Housing Material: Polyamide / V0; IP protection class: IP20; Ambient Temperature: -25 ... +55 °C; Terminal connection: Removable screw terminals; Depth: 118 mm. Article number: 101218030. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP20
  • • Ağırlık: 300 g
  • • Sertifika: TÜV, cULus, CCC cULus TÜV

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1
  • • EN IEC 62061
  • • EN IEC 60947-5-5
  • • EN IEC 60204-1
  • • EN IEC 60947-1

Product Features

  • • Simple and flexible parameter setting
  • • No programming skills required
  • • 18 safe inputs for the redundant inquiry of all common safety sensors
  • • 4 safety semi-conductor outputs
  • • 2 safety relay outputs
  • • 4 optional signalling outputs
  • • Replaces up to 8 safety-monitoring modules up to PL e / SIL 3
  • • Error and status messages in plain text
  • • Multilingual menu navigation via colour display

Technical Specifications

Depth 118 mm
EPLAN Yes
Mounting Snaps onto standard DIN rail to EN 60715
Notice Valid for dual channel and 60% relay load
Category 2 | 4
Width 52.5 mm
PFH value 1.78 x 10⁻⁸ /h
EMC rating EMC-Directive
Height 100 mm
Demand rate high or continuous
Start input Yes
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type DC
Shock resistance 30 g / 11 ms
Start-up test Yes
Mission time 20 Year(s)
Net Ağırlık 300 g
Bağlantı Tipi rigid or flexible
Climatic stress EN 60068-2-2 | EN 60068-2-1 | EN 61496
Gross weight 300 g
Feedback circuit Yes
Housing Material Polyamide / V0
Contact material Tin
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 12 VDC -10 % / +10 % | 24 V
Relative humidity 15 ... 90 %
Vibration resistance 10 … 57 Hz, amplitude 0.75 mm
Max. cable cross-section 2.5 mm²
Operating current 100 mA
IP protection class IP20
Ambient Temperature -25 ... +55 °C
Performance level e | d
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Reset edge detection Yes
Switching thresholds 18 V … 28.8 V | -3 V … 2 V (LOW)
Terminal designations IEC/EN 60947-1 | IEC 61131-2
Terminal connection Removable screw terminals
Cross-circuit detection Yes
Input resistance at GND 10,000 Ω
Short circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Note (Relative humidity) non-condensing
Maks. Ortam Sıcaklığı +55 °C
Design of control elements short-circuit proof, p-type (Q2 und Q3) | Limited short-circuit protection, p-type | short-circuit proof, p-type / n-type (Q0/0N and Q1/1N)
Earth connection detection Yes
Operating voltage, maximum 26.4 VDC
Operating voltage, minimum 21.6 VDC
Relative humidity, maximum 90 %
Relative humidity, minimum 15 %
Tightening torque of Clips 0.6 Nm
Overvoltage category 3 | III
Current consumption at 24 V 6 mA
Leakage current Ir, maximum 2 mA
Nominal Çalışma Voltajı 12 VDC
Number of signalling outputs 4
Switching frequency, maximum 0.1 Hz
Note (application conditions) Safety light curtain | Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Diagnostic Coverage (DC) Level 99 %
Hardware fault tolerance (HFT) 1
Electrical fuse rating, maximum 3 A
Depolama / Taşıma Sıcaklığı -25 ... +75 °C
Current, Utilisation category AC-1 4 A
Current, Utilisation category DC-1 4 A
Integrated Display, Supply Voltage Yes
No-load supply current I0, typical 500 mA
Number of digital fail-safe inputs 14
Voltage, Utilisation category AC-1 250 VAC
Voltage, Utilisation category DC-1 24 VDC
Common Cause Failure (CCF), minimum 65
Current consumption at 24V, maximum 500 mA
Current, Utilisation category AC-15 3 A
Current, Utilisation category DC-13 4 A
Required rated short-circuit current 1,000 A
Integral system diagnostics, status Yes
Note (Electrical data, Fuse rating) slow blow
Number of fail-safe analogue inputs 2
Number of fail-safe digital outputs 4
Number of relay outputs (1-channel) 2
Voltage, Utilisation category AC-15 230 VAC
Voltage, Utilisation category DC-13 24 VDC
Absicherung des Sicherheitsausganges 4 A gL/gG D-fuse
Safe Failure Fraction (SFF), minimum 90
Number of digital fail-safe in-/outputs 4
Rated operating current (safety outputs) 700 mA
Storage and transport temperature, maximum +75 °C
Storage and transport temperature, minimum -25 °C
Number of pulse outputs (test pulse output) 3
IP Degree of protection of the installation space IP54
Safety Integrity Level (SIL), suitable for applications in 2 | 3