SRB207AN/1-230VAC
Order No 101176606
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SRB207AN/1-230VAC

SRB207AN/1-230VAC — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +45 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101176606. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 400 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-5
  • • EN IEC 60947-5-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1
  • • EN IEC 62061
  • • EN ISO 13849-1

Product Features

  • • Suitable for the signal processing of outputs with contact sensors
  • • Suitable for the signal processing of outputs with contact sensors
  • • 2 safety contacts, STOP 0
  • • 6 Signalling outputs
  • • Multi-evaluation of up to 6 safety guards

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
EMC rating EMC-Directive
Height 100 mm
Start input Yes
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Shock resistance 10 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 400 g
Number of LEDs 3
Climatic stress EN 60068-2-78
Electronic Fuse Yes
Frequency range 50 Hz | 60 Hz
Gross weight 400 g
Category, Stop 0 3
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 48 ... 240 VAC
PFH value, Stop 0 2.00 x 10⁻⁷ /h
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Ambient Temperature -25 ... +45 °C
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Reset edge detection Yes
Utilisation category AC-15 | DC-13
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) To secure 6 guard doors up to PL d and Category 3 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge. | Start button (S) with edge detection | The feedback circuit monitors the position of the contactors K3 and K4. | Monitoring 6 guard door(s), each with a magnetic safety sensor of the BNS range | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Type of voltage range AC
Terminal connection Screw terminals
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 2
Maks. Ortam Sıcaklığı +45 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Internal operating voltage Ui | Position relay K2
Utilization Category AC-15 6 A | 230 VAC
Utilization Category DC-13 6 A | 24 VDC | 24 VDC / 6 A
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 0
Overvoltage category II | 2
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 48 ... 240 VAC
Electrical power consumption 6.8 W
Number of signalling outputs 6
Note (application conditions) Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Performance Level, stop 0, up to d
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Pull-in delay at RESET, typically 30 ms
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Number of NO (Normally Open) Contacts 6
Number of NC (Normally Closed) Contacts 6
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 240 VAC
Rated control voltage at AC 60 Hz, maximum 240 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 48 VAC
Rated AC voltage for controls, 60 Hz, minimum 48 VAC
IP Degree of protection of the installation space IP54
Drop-out delay in case of "emergency stop", maximum 20 ms
Pull-in delay at automatic start, maximum, typically 120 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in 2