SRB302X3-24/115V — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +60 °C | -30 ... +60 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101183197. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 520 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-5
  • • EN IEC 60947-5-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1
  • • EN ISO 13849-1
  • • EN IEC 62061

Product Features

  • • Suitable for the signal processing of outputs with contact sensors
  • • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • • 3 safety contacts, STOP 0
  • • 2 Signalling outputs

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
Category 4
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
PFH value 2.00 x 10⁻⁸ /h
EMC rating EMC-Directive
Height 100 mm
Start input Yes
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type DC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 520 g
Number of LEDs 3
Ripple voltage 10 %
Climatic stress EN 60068-2-78
Electronic Fuse Yes
Frequency range 50 Hz | 60 Hz
Gross weight 520 g
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VDC -10 % / +20 % | 24 ... 230 VAC -15 % / +10 %
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Max. cable cross-section 2.5 mm²
Ambient Temperature -25 ... +60 °C | -30 ... +60 °C
Performance level e
Mechanical life (min.) 10,000,000
Reset edge detection Yes
Utilisation category AC-15 | DC-13
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) (H2) = Feedback circuit | The control recognises cross-short, cable break and earth leakages in the monitoring circuit. | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | 2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R). | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Type of voltage range AC
Terminal connection Screw terminals
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 3
Maks. Ortam Sıcaklığı +60 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Position relay K2
Utilization Category AC-15 6 A | 230 VAC
Utilization Category DC-13 6 A | 24 VDC | 24 VDC / 6 A
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 2
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VDC -15%/+20%, residual ripple max. 10% | 24 ... 230 VAC | 115 VAC -15% / +10% | 24 VDC | 24 VAC -15% / +10%
Electrical power consumption 5 VA | 2.5 W
Note (application conditions) Safety light curtain | Pull-wire emergency stop switches | Emergency-Stop button | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Diagnostic Coverage (DC) Level > 99 %
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Pull-in delay at RESET, typically 20 ms
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Rated control voltage at DC, maximum 28.8 VDC
Number of NC (Normally Closed) Contacts 2
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 26.4 VAC
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 60 ms