Note
All indications including the conductor ferrules. | Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Mounting
Screws
Category
3 | 1
Cable Cross-Section
1 mm² ... 1 mm²(All indications including the conductor ferrules.) | 1 x 0.5 mm² ... 1 x 1.5 mm² (All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Strip length
8 mm
Mission time
20 Year(s)
Latching force
20 N
Net Ağırlık
480 g
Bağlantı Tipi
Screw terminals
Power to unlock
Yes
Gross weight
480 g
Housing Material
Glass-fibre, reinforced thermoplastic
Contact material
Silver
Min. cable cross-section
1 x 0.5 mm²
Scope of delivery
The actuator TZ/CO is included in delivery.
Sensor length
41 mm
Max. cable cross-section
1 x 1.5 mm²
IP protection class
IP67 | IP65
Ambient Temperature
+0 ... +50 °C | -25 ... +55 °C
Performance level
c | d
Sensor width
129 mm
Conventional thermal current
4 A
Working Principle
electromechanical
Switching principle
Slow action
Mechanical life (min.)
1,000,000
Sensor height
92.5 mm
Magnet switch-on time
100 %
Maks. Sigorta Değeri
4 A gG D-fuse to DIN EN 60269-1
Positive break travel
3.5 mm
Max. actuating speed
0.3 m/s
Tool for the connection
SL / PH 2
Min. Ortam Sıcaklığı
+0 °C
Note (Delivery capacity)
Not available!
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity)
non-condensing | non-icing
Number of safety contacts
2 | 2 / 3 / 4
Maks. Ortam Sıcaklığı
+50 °C
Type of the fixing screws
3x M6
Utilization Category AC-15
230 VAC / 4 A / Screw terminals
Utilization Category DC-13
24 VDC / 4 A / Screw terminals | 24 VDC / 4 A
Number of auxiliary contacts
0 / 1 / 2
Max. switching frequency
1,200 /h
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Positive break force, minimum
20 N
Rated impulse withstand voltage (Uimp)
2.5 kV
Number of actuating directions
4
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Rated insulation voltage (Uᵢ)
250 VAC
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
8.5 W
Coding level according to EN ISO 14119
Low
Tightening torque of electrical connection
0.8 Nm
Positive break force per NC contact, minimum
20 N
Holding force FZh in accordance with EN ISO 14119
1,500 N
Tightening torque of the fastening screws for the housing cover, maximum
0.8 Nm
Tightening torque of the fastening screws for the housing cover, minimum
0.8 Nm