ZQ 900-02
Order No 161186146
Certificates cULus cULus, CCC
Schmersal Safe Switching and Monitoring Rope / Pull-Wire Emergency Stop

ZQ 900-02 Rope / Pull-Wire Emergency Stop

ZQ 900-02 — Schmersal Rope / Pull-Wire Emergency Stop. Key specifications: Switching principle: Snap action; Switching element: 2 NC contact; Housing Material: Metal, zinc die-cast; IP protection class: IP67 | IP65; Ambient Temperature: -25 ... +70 °C. Article number: 161186146. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 1,400 g
  • • Sertifika: cULus cULus, CCC

Standards

  • • EN ISO 13850
  • • EN IEC 60947-5-1
  • • EN IEC 60947-5-5
  • • EN ISO 13849-1

Product Features

  • • 3 cable entries M 20 x 1.5
  • • Metal enclosure
  • • one-side operation / wire up to 75 m long
  • • Release push button
  • • Position indicator
  • • Robust design
  • • Large wiring compartment
  • • Twisting of towing eye not possible
  • • External watertight collar
  • • wire pull and breakage detection

Technical Specifications

Note All indications including the conductor ferrules.
CADENAS Yes
General note For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. | The screwed G24-M20 indicator lamp must be ordered separately, see accessories. | Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. | As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. | At 2 m ... 5 m distance intermediate wire supports are required, see accessories
Cable Cross-Section 0.75_2.5_PMAW00000660 | 0.75 mm² ... 2.5 mm²(All indications including the conductor ferrules.)
Mission time 20 Year(s)
Indicator lamp No
Net Ağırlık 1,400 g
Bağlantı Tipi Screw terminals M20 x 1.5
Gross weight 1,400 g
Housing Material Metal, zinc die-cast
Contact material Silver
Min. cable cross-section 0.75 mm²
Sensor length 69.7 mm
Max. cable cross-section 2.5 mm²
IP protection class IP67 | IP65
Ambient Temperature -25 ... +70 °C
Sensor width 71.5 mm
Conventional thermal current 6 A
Switching element 2 NC contact
Switching principle Snap action
Mechanical life (min.) 1,000,000
Utilisation category AC-15 | DC-13
Maks. Sigorta Değeri 6 A gG D-fuse
Traceparts, product ID 33-22052019-082229
Housing Coating Material painted
Min. Ortam Sıcaklığı -25 °C
Number of safety contacts 1 / 2 / 3 / 4 | 2
Maks. Ortam Sıcaklığı +70 °C
Utilization Category AC-15 4 A | 230 VAC
Utilization Category DC-13 24 VDC / 1 A | 24 VDC | 1 A
Relative humidity, maximum 95 %
Number of auxiliary contacts 1 / 2
Length of the wire, maximum 75 m
ACE reference article number 16771601
Height of the Sensor, maximum 236.3 mm
Height of the Sensor, minimum 220.3 mm
Material of the housing cover Glass-fibre, thermoplastic
Rated impulse withstand voltage (Uimp) 6 kV
B10D Normally-closed contact (NC) 100,000
Rated insulation voltage (Uᵢ) 500 V

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3