PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Coding
Individual coding, multiple teaching
Category
2 | 4
Latching
Yes
General note
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
PFD value
4.50 x 10⁻⁵ | 1.80 x 10⁻⁴
PFH value
2.00 x 10⁻⁹ /h | 5.20 x 10⁻¹⁰ /h
Voltage type
DC
Shock resistance
30 g / 11 ms
Power to lock
Yes
Series-wiring
Yes
Mission time
20 Year(s)
Manual release
Yes
Net Ağırlık
1,100 g
Bağlantı Tipi
Connector M12, 8-pole, A-coded
Gross weight
1,100 g
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
III
Safety functions
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Scope of delivery
Actuator must be ordered separately.
Sensor length
178 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
Operating current
800 mA
Frequency band RFID
125 kHz
IP protection class
IP6X (EN 60079-31) | IP64 (EN 60079-7)
Ambient Temperature
-25 ... +55 °C | +0 ... +50 °C
Performance level
e | d
Sensor width
93 mm
Working Principle
RFID
Mechanical life (min.)
1,000,000
Note (Energy impact)
with stainless steel CL/CR protective enclosure
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
40.3 mm
Switching thresholds
-3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
+0 °C
Note (Relative humidity)
non-condensing | non-icing
Switch distance, typical
2 mm
Voltage drop Ud, maximum
2 V
Duration of risk, maximum
200 ms
Maks. Ortam Sıcaklığı
+50 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
EX-AZ/AZM300-B1
Type of the fixing screws
2x M6
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Explosion protection zones
22 | 2
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05
Note (Mechanical lifetime)
When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Relative humidity, maximum
93 %
Time to readiness, maximum
5,000 ms
Utilisation category DC-12
24 VDC / 0.05 A | 24 VDC / 0.25 A | 24_0.05 | 24_0.25
Overvoltage category
3 | III
Current consumption at 24 V
5 mA | 10 mA
Designation, Magnet control
IN
Designation, Safety outputs
Y1 and Y2
Holding force Fmax, maximum
1,500 N
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Solenoid interlock monitored
Yes
Switching frequency, maximum
0.5 Hz
Test pulse duration, maximum
5 ms | 1 ms | 0.5 ms
Test pulse interval, minimum
40 ms | 100 ms
Test pulse interval, typical
1,000 ms
Explosion protection category
3G | 3D
Material of the fixing screws
Stainless steel (V4A)
Rated impulse withstand voltage (Uimp)
0.8 kV
Number of actuating directions
1
Classification ZVEI CB24I, Sink
C1 | C0 | C2
Designation, Diagnostic outputs
OUT
Electrical fuse rating, maximum
2 A
Length of sensor chain, maximum
200 m
Explosion protection designation
D II 3G Ex ic IIC T5 Gc X | D II 3D Ex tc IIIB T95°C Dc X
Note (Type of the fixing screws)
Property class min. 8.8
Transmitter output RFID, maximum
-6 dBm
Classification ZVEI CB24I, Source
C3 | C1 | C2
Depolama / Taşıma Sıcaklığı
-10 ... +90 °C
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-7 | EN 60079-31
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Assured switching distance "ON" Sao
1 mm
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
20 mm
External wire and device fuse rating
2 A gG | 2 A gG (Connector M12, 8-pole, A-coded)
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
High
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Current consumption with magnet ON, peak
350 mA / 200 ms
Energy impact (protective case), maximum
7 J
Storage and transport temperature, maximum
+90 °C
Storage and transport temperature, minimum
-10 °C
Current consumption with magnet ON, average
200 mA
Tightening torque of the fixing screws, maximum
8 Nm
Holding force FZh in accordance with EN ISO 14119
1,150 N
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
2 | 3
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Reaction time, switching off safety outputs via safety inputs, maximum
1.5 ms